Product Application:
The treating instrument is a kind of treating equipment for nerve and blood vessel disease, applicable to the nerve medicine, tapetum surgery, recovery and treatment, blood vessel section, orthopedics, advanced case sickroom, operative room, etc. in hospitals of all levels.
Air wave pressure circulation technique: It adopts the program controlled air bag, which wraps the body or limb, with each air bag equally divided into eight independent small chambers, carrying on ring shape pressing according to the different treating mode setup, and forming certain gradient pressure. The air inflation and discharge process is given from distant place to near terminal in sequence, available to press back the venous haematoporphyrin and lymph fluid silting at the abdominal part and the body for effective blood circulation, having directivity, graduation, and accumulative "extrusion" action, and able to increase the venous return and effective circular blood volume; In the mean time, since the surrounding blood vessel function is improved, in the process of the air bag discharging, the corresponding vasodilator of the part will be expanded, thus reducing aorta shooting haematoporphyrin output resistance, with the heart after load reduced, and reducing cardiac muscle oxygen consumption.
The bio-wave digital frequency synthesis technique: Digital circuit controlled by microprocessor is fed with different input data, and generates different waveforms, which are amplified and detected, obtaining the waveforms needed by this treating instrument. The waveforms are then act on the part needed on human body through two groups of conductive skin adhesive electrode sheets, generating dynamic bio-electric field at the part needed, obtaining the functions such as expanding blood vessel, improving microcirculation, attenuating inflammation factors and adjusting the body organs through a comprehensive oscillating effect.
Summing up the above techniques: this treating instrument of airwave pressure circulation is a kind of effective method of none trauma, settling whole body or partial nerve and blood vessel paroxysm. Comparing with the common single-item physical factor treating in the clinic, LGT-2200W treating instrument of airwave pressure circulation can not only make the sufferer be able to accept compound treating of multiple kinds and multiple parts, but also the double physical factor can complement the treating action each other, generating treating effect of 1+1> 2.
Main Performance and Technical Parameters
1 Main Performance
1.1 The output pulse frequency of treating instrument should not be greater than 1000 Hz;
1.2 The effective value of maximum output amplitude of treating instrument should not be greater than 25 V;
1.3 The rated load impedance of treating instrument rated load impedance should be 500 Ω, allowance ±50 Ω;
1.4 The pulse width of treating instrument should be in the range of 0. 15ms~100ms.
1.5 The electric quantity of each pulse should be greater than 7 μC at the maximum output amplitude of treating instrument.
1.6 The energy of single pulse maximum output of skin electrode should not be over 300 mJ.
1.7 The pressure setting range of treating instrument 5~25 kpa continuously adjustable
1.8 Operating mode: Intermittent
2. Main technical parameter
2.1 Input power: 130W+10%;
2.2 Digital display scope of time: 00~99 (unit: Minute);
2.3 Digital display scope of bio-wave frequency: 20~7920~79(15~38 Hz pulse frequency);
2.4 Digital display scope of bio-wave intensity: 20~99 (0~5.9 V);
2.5 Digital display scope of airwave mode: 01~08;
2.6 Digital display scope of airwave pressure intensity: 05~25kpa;
2.7 Weight of treating instrument: 35kg;
2.8 Outline dimensions of treating instrument
a) Main system outline dimensions: 430mm (W) × 380mm (L) × 175mm (H);
b) Cart outline dimensions: 430mm (W) × 520mm (L) × 750mm (H)
2.9 Transport and storage conditions
a) Environmental temperature: -10~55℃;
b) Relative humidity: ≤95%;
c) Air pressure: 50.0-106.0 kpa;
d) Without corrosive gas, well ventilated room.
2.10 Normal operating conditions
a) Environmental temperature: 5~40℃;
b) Relative humidity: ≤80%;
c) Air pressure: 86.0-106.0 kpa;
d) Power supply: AC220 V ±10%, 50Hz ±2%;
e) Warm-up time: 2 min.
Application Scope
It is applicable to assistant treatment for cerebral accident, tapetum external injury, tapetum after operation, limb dysfunction and external cycle non plunger angitis caused by spinal cord pathological change, and to prevent phlebothrombosis forming, and to release body edema.